A contamination survey finds radioactive material on surfaces and in spaces where it should not be. You move a detector across floors, walls, benches and objects in a pattern that leaves no area unchecked. BIL Solutions breaks the process into preparation, scanning and recording so you can work through a property methodically and know what you found.

Plan your survey route before you touch the detector

Walk the property and divide it into zones. A zone is a room, a section of corridor or a defined outdoor area. Number each zone and sketch its shape on paper. Mark doors, windows, work surfaces and anything that sits against a wall.

List the zones in the order you will survey them. Start farthest from the exit and work back towards it so you do not walk through areas already cleared. Note which zones are expected to have elevated readings—a laboratory bench where sources are handled, a storage cupboard—and which should read close to background.

Check your detector works. Power it on in a clean area away from the property and record the count rate. This confirms the instrument responds and gives you a reference for later.

Establish your baseline reading outdoors

Before entering the property, take a baseline reading in an open outdoor location at least ten metres from any building. Hold the detector at waist height and let it count for one minute. Write down the value and the time.

This reading is your background reference. Readings inside the property are compared against it. A count significantly higher than baseline suggests contamination; a count close to baseline suggests the surface is clean.

Repeat the baseline measurement after the survey to confirm the detector has not drifted and that you have not carried contamination out with you.

Scan surfaces using a consistent technique

Hold the detector probe close to the surface—within a centimetre for contamination monitors designed for this work, slightly farther for general survey instruments. Move the probe slowly and steadily. A speed that covers the probe's width each second keeps the dwell time high enough to detect weak signals.

Work in overlapping passes. Scan a bench from left to right, then step the probe back by half its width and scan right to left. This pattern ensures every part of the surface passes under the detector window. Overlapping prevents gaps where contamination could hide.

Scan in this order within each zone:

  1. Floors, starting at the corner farthest from the door and working in strips towards the exit.
  2. Horizontal surfaces—benches, shelves, windowsills—from back to front.
  3. Vertical surfaces—walls, cupboard doors, equipment sides—from top to bottom.
  4. Small objects and tools, turning each one to scan all sides.

Keep the probe's orientation constant. Many detectors respond differently depending on whether radiation strikes the window straight on or at an angle. Keeping the window parallel to the surface reduces variation in readings.

Watch for hot spots

A hot spot is a localised area where the count rate jumps above the surrounding readings. When the count climbs sharply, stop moving and hold the probe still for ten seconds. Note the peak count and the exact location—measure from a fixed point such as a corner or a door frame.

Mark the spot with tape or a marker. Do not touch it with your hands. Move on and continue the survey; you will return to investigate hot spots after the initial scan is complete.

Scan areas where contamination spreads

Some surfaces are more likely to collect radioactive material than others. Door handles transfer contamination from hands. Floors near work areas collect dust and spills. Ventilation grilles trap airborne particles. Scan these areas with extra care and record even modest increases in count rate.

Surface type Why it matters Scanning priority
Work benches Direct contact with sources High
Floors Collect dropped material and tracked contamination High
Door handles Transfer from hands Medium
Walls Splashes and airborne deposition Medium
Ceilings Rarely contaminated unless incident occurred Low

Record every reading as you go

Write down the count rate, the location and the time for each measurement. A typical log entry names the zone, describes the surface and states the value. Carry a notebook or a clipboard with printed sheets; electronic records are faster but paper cannot crash mid-survey.

Note anything unusual. A discoloured patch on a bench, a crack in the floor, a stain on the wall—these features may explain elevated readings or identify where material entered. Photograph hot spots and mark their positions on your sketch.

Record the detector's response time. Some instruments average counts over several seconds; others update every second. Knowing the response time tells you how long to hold the probe over a suspect area to get a stable reading.

Investigate hot spots after the initial sweep

Return to each marked location and take a static measurement. Place the probe directly over the hot spot and count for one minute. This longer dwell time reduces statistical variation and gives a more reliable value.

Measure the extent of the hot spot by scanning outwards from the centre in all directions until the count drops back to the zone's average reading. Measure the contaminated area's dimensions and sketch its shape.

If the hot spot is movable—a tool, a container, a piece of equipment—isolate it. Place it in a designated area away from clean surfaces and mark it for decontamination or disposal. Do not attempt to clean it during the survey; finish the survey first.

Compare readings across zones

Once every zone has been scanned, review your log. Group the readings by zone and calculate each zone's average count rate. Compare these averages to your outdoor baseline.

A zone with an average close to baseline is likely clean. A zone with an average well above baseline may have widespread low-level contamination or several localised hot spots. The pattern of readings tells you whether contamination is confined to specific surfaces or distributed throughout the space.

Check for trends. Readings that rise as you move towards a particular area suggest a source nearby. Readings that cluster around certain surfaces—floors, not walls—suggest tracking rather than airborne spread. Understanding energy compensation helps explain why some detectors show different responses to the same contamination, as described in this article on detector response.

Document your findings clearly

Summarise the survey in a short report. State the date, the property address, the detector used and the person who performed the survey. List each zone, its average reading and any hot spots found. Attach your sketches and photographs.

Describe what you did with contaminated items. If you isolated a tool or marked a floor area, say where it is now and what needs to happen next. If you found no contamination, state that clearly.

File the report where someone else can find it. A contamination survey is a record of the property's condition at a moment in time. Future surveys compare against it to see whether contamination has spread or whether decontamination worked.

Understand when counts mislead

Not every elevated reading means contamination. Background radiation varies with location, building materials and weather. Granite worktops, concrete with fly ash and old ceramic tiles can all produce higher counts than timber or plaster.

A detector held near a brick wall may read higher than the same detector in the centre of the room, even when no contamination is present. Record these baseline differences during your first survey of a property so later surveys do not mistake them for new contamination.

Dead time affects readings at high count rates. When a detector is overwhelmed by radiation, it undercounts. If a reading seems implausibly low given visible contamination, suspect dead time. Recognising dead time prevents you from underestimating the severity of contamination.

Start with one room this week

A full-property survey takes planning and focus. Begin with a single room where you know sources have been handled. Walk through the steps on a small scale and refine your technique before tackling larger areas.

  • Mark out a one-room survey zone on paper tonight.
  • Take a baseline reading outdoors tomorrow and note it.
  • Scan the floor in overlapping passes, recording as you go.
  • Compare your room average to the outdoor baseline and write one sentence summarising what you found.

Each survey sharpens your ability to spot patterns, judge readings and move efficiently. The method stays the same whether you are clearing a single bench or an entire building.

#Survey technique #Contamination monitor #Surface contamination #Radiation safety

Download PDF: Property Contamination Survey Checklist PDF, 30 KB

Further reading

  1. Radiation Measurementsen.wikipedia.org

Frequently asked questions

What equipment do I need to survey a property for contamination?

You need a contamination monitor or survey meter with a probe sensitive to the type of radiation you expect, a notebook or printed log sheets, a tape measure, marking tape and a camera or phone for photographs. A watch or timer helps you keep static measurements consistent.

How do I know if a reading means contamination or just background?

Compare the reading to your outdoor baseline taken before the survey. A count significantly higher than baseline suggests contamination, while a count close to baseline indicates the surface is likely clean. Building materials and location cause natural variation, so record these differences during your first survey.

What should I do if I find a hot spot during a contamination survey?

Mark the location with tape, record the peak count and exact position, then continue your survey without touching the spot. After completing the initial sweep, return to take a longer static measurement and measure the contaminated area's extent. Isolate movable contaminated items in a designated area.