Practical Guides

Measuring radon at home: 3 detector types you can use

BIL Solutions Editorial Team 9 min read · Updated
Measuring radon at home: 3 detector types you can useSave
Share

You measure radon levels at home using detectors that respond to alpha particles emitted when radon gas decays. These instruments range from passive devices you leave in place for a set period to electronic monitors that give you a reading within hours. The method you choose depends on whether you need a quick snapshot or a long-term average, and whether you prefer to analyse results yourself or send the detector to a laboratory. BIL Solutions walks you through the techniques and devices that make radon measurement practical for residential use.

Understanding what radon detectors actually measure

Radon detectors do not measure the gas directly. Instead, they detect the alpha radiation produced when radon-222 atoms decay inside your living space. Radon is a radioactive noble gas that seeps into buildings from the ground, and because it is chemically inert, it does not bind to surfaces or react with materials. What you measure is the activity of radon and its short-lived decay products in the air, usually expressed in becquerels per cubic metre.

Alpha particles travel only a few centimetres in air and cannot penetrate skin, but they interact strongly with detector materials. This property lets purpose-built instruments distinguish radon from other sources of background radiation. The unit of measurement matters: laboratories and regulators in many countries report results in becquerels per cubic metre, while older literature and some devices use picocuries per litre.

Choosing between short-term and long-term measurement

Short-term tests run for a few days up to a week and give you a quick indication of radon levels under the conditions present during that window. They are useful for screening a property before purchase or for checking a specific room. Long-term tests run for three months or more and average out daily and seasonal variations in radon concentration, which can be substantial.

Radon levels fluctuate with ventilation, soil moisture, barometric pressure and the heating cycle of a building. A short-term reading taken in summer with windows open will typically underestimate the annual average, while a winter measurement with the house sealed may overestimate it. For a reliable assessment of your exposure over a year, a long-term test is the standard approach. If you need an answer quickly, take a short-term reading but interpret it as provisional.

When to use each type of test

  • Short-term: property surveys, identifying the room with the highest concentration, verifying that mitigation work has reduced levels.
  • Long-term: assessing your annual average exposure, meeting regulatory guidance for residential radon measurement, deciding whether remedial action is needed.

Using alpha scintillation cells for passive measurement

An alpha scintillation cell is a small sealed container coated inside with zinc sulphide, which emits a flash of light each time an alpha particle strikes it. You open the cell in the room you want to test, leave it for the specified exposure period—often three to seven days—then seal it and post it to a laboratory. The lab places the cell against a photomultiplier tube in darkness and counts the light flashes to calculate the radon concentration during your exposure window.

These devices require no power and no expertise to deploy. Write down the date and time you opened the cell, and the date and time you sealed it again. Keep the cell away from draughts, at least a metre from external walls and half a metre above the floor. Do not place it in a cupboard or behind furniture. The laboratory will send you a report showing the measured concentration and comparing it to any action level that applies in your jurisdiction.

Deploying electret ion chambers in multiple rooms

An electret ion chamber uses a charged disc of Teflon inside a small plastic chamber. Radon and its decay products ionise the air inside, and the ions neutralise some of the electret's surface charge. The laboratory measures the voltage drop after exposure and calculates the radon concentration from it, taking into account the exposure duration and chamber volume.

Electrets are passive, lightweight and can be reused many times, which makes them economical for testing several rooms or floors in one go. You open the chamber, note the start voltage if the laboratory provides a reader, expose it for the recommended period, then close and return it. The sensitivity depends on how long you leave the chamber open: longer exposures suit lower radon levels, while shorter exposures prevent the electret from discharging completely in high-radon environments.

Practical points for electret deployment

Place chambers on a shelf or table at breathing height, away from humidity sources such as bathrooms and kitchens. Do not move the chamber once you have opened it. If the electret voltage drops below a threshold during exposure, the reading becomes unreliable, so match the exposure duration to the expected radon level. The laboratory's instructions will specify which chamber type and exposure time to use based on your initial estimate or previous screening results.

Running a continuous radon monitor for real-time data

A continuous radon monitor is an electronic instrument that samples air actively, measures alpha particles from radon decay products and displays a running concentration on a screen. These devices update every hour or every few hours, letting you see how radon levels change with ventilation, weather and time of day. Most models log data over weeks or months and calculate rolling averages.

Continuous monitors cost more than passive detectors but deliver immediate feedback. Set the device in the room of interest, plug it in and let it run. The first reading stabilises after a few hours; a reliable daily average emerges within two days. For a meaningful long-term average, leave the monitor in place for at least a month. Many instruments display both the current reading and cumulative averages over different periods.

Interpreting fluctuations on the display

Watch for patterns rather than single peaks. A spike in the morning may reflect reduced ventilation overnight, while a drop in the afternoon often follows increased air exchange. Seasonal trends appear over months: radon concentrations typically rise in winter when buildings are sealed and fall in summer when windows stay open. Use the long-term average to assess health risk; use the short-term trace to understand how your building behaviour affects radon entry.

Selecting the detector that suits your situation

Your choice depends on budget, urgency and the level of detail you want. Passive detectors are inexpensive, require no batteries or calibration and suit one-off assessments. Continuous monitors give you ongoing visibility and let you test the effect of ventilation changes or remedial work in real time. The table below compares the three main types.

Detector type Exposure period Analysis Cost
Alpha scintillation cell 3–7 days Laboratory Low
Electret ion chamber 2 days to 12 months Laboratory Low to moderate
Continuous monitor Hours to months On-device display Moderate to high

If you are measuring radon for the first time and want to know whether your home exceeds the action level, an alpha scintillation cell or electret chamber deployed for three months will give you the answer at low cost. If you are testing mitigation measures or need to monitor an area continuously, a continuous monitor justifies the higher outlay. Some testing services offer both: a short-term screen to decide whether long-term monitoring is warranted, followed by a second deployment if the initial result is elevated.

Following the measurement procedure step by step

Correct placement and handling are as important as the detector itself. The steps below apply to passive detectors; continuous monitors follow similar principles but stay powered throughout.

  1. Choose the room: start with the lowest occupied level of the building—typically the ground floor or basement—because radon concentrations are usually highest there.
  2. Position the detector: place it at breathing height, away from draughts, external walls and sources of moisture; do not move it once the exposure period begins.
  3. Record the deployment: write down the date, time, location and any conditions such as whether windows were open or closed during the test.
  4. Close the detector: seal it at the end of the exposure period, noting the date and time, and send it to the laboratory within the timeframe the instructions specify.
  5. Interpret the result: compare the reported concentration to the action level in your jurisdiction and decide whether further measurement or remedial action is needed.

Avoiding common mistakes

Do not test during unusually windy weather or when the building is unoccupied for long periods, as these conditions produce atypical readings. Keep doors and windows closed for the period specified in the detector's instructions—usually at least 12 hours before deployment for short-term tests. Do not place detectors in rooms used only occasionally, such as spare bedrooms or storage areas, unless you specifically want to measure those spaces. Test the living areas where you spend most of your time.

Acting on the results you receive

Once you have your radon concentration, compare it to the reference level set by health authorities. In the UK, the action level is 200 becquerels per cubic metre as an annual average. If your result is below that threshold, no action is required. If it is above, consider remedial measures: improving underfloor ventilation, sealing cracks in floors and walls, or installing a radon sump that vents the gas harmlessly outside.

A result just above the action level does not demand immediate alarm, but it does warrant a response within a reasonable timeframe. A result several times higher calls for prompt investigation. Radon remediation is straightforward in most buildings and typically reduces levels by half or more. After installing any remedial system, repeat the measurement to verify that the intervention has worked.

Keep records of all measurements, including where and when detectors were placed, what the conditions were and what the results showed. If you move house, share the radon measurement history with the new occupants. If you are buying a property, ask whether radon testing has been carried out and review the results before completing the purchase. For more on the types of ionising radiation and how they differ, see our guide to alpha, beta and gamma radiation.

Maintaining accuracy over repeated measurements

Passive detectors are single-use or have a limited number of reuses; electrets lose sensitivity over time and must be recharged or replaced. Continuous monitors require periodic calibration to maintain accuracy, typically once a year or after a set number of operating hours. Follow the manufacturer's service schedule and keep a record of calibration dates.

If you are using a continuous monitor, clean the inlet filter according to the manual's guidance and check that the fan is running. Dust and debris can block airflow and distort readings. Store passive detectors in their sealed packaging until you are ready to deploy them, and return them to the laboratory promptly after exposure. Delay between sealing and analysis can lead to underestimation of the true radon level, because the decay products lose activity over time.

To understand how other radiation detectors function, read our explanation of scintillation detectors and how Geiger counters work. For practical checks on your detector's operation, see testing a Geiger counter.

#Radon #Alpha radiation #Scintillation detector #Dosimeter

Download PDF: Radon measurement checklist for your home PDF, 30 KB

Further reading

  1. Radiation Measurementsen.wikipedia.org
  2. Principles of Radiation Measurement [MOE]env.go.jp

Frequently asked questions

Do I need to measure radon in my home?

Measure radon if you live in an area known for elevated levels, if your home is built on soil that allows gas to enter easily, or if you want to know your actual exposure. Health authorities recommend testing in basements and ground-floor living areas.

How long should a radon test run?

A short-term test runs for three to seven days and gives you a quick snapshot. A long-term test runs for at least three months and averages out seasonal and daily variations, which makes it more reliable for assessing your annual exposure.

Can I use a Geiger counter to measure radon?

Standard Geiger counters respond poorly to alpha radiation and are not suitable for measuring radon gas. Use a detector specifically designed for radon, such as an alpha scintillation cell, electret ion chamber or continuous radon monitor.

What radon level should I be concerned about?

In the UK, the action level is 200 becquerels per cubic metre as an annual average. Levels above this warrant consideration of remedial measures to reduce your exposure.

Do radon levels change throughout the year?

Yes. Radon concentrations typically rise in winter when buildings are sealed and ventilation is reduced, and fall in summer when windows and doors are open more often. This is why long-term measurements give a more accurate picture.

Where should I place a radon detector in my home?

Place it in the lowest occupied level of the building, at breathing height, away from draughts, external walls and sources of moisture. Do not put it in a cupboard or behind furniture.

How accurate are passive radon detectors?

Passive detectors such as alpha scintillation cells and electret ion chambers are accurate when deployed correctly and analysed by accredited laboratories. They are the standard method for residential radon measurement in many countries.

Can I reuse a radon detector?

Alpha scintillation cells are typically single-use. Electret ion chambers can be recharged and reused multiple times. Continuous monitors remain in service for years, provided they are calibrated according to the manufacturer's schedule.

Last updated: